Compute average precision vs trapezoid AUC-PR with scikit-learn

Quick Overview

Implement a function that returns both the average precision and the trapezoidal area under the precision-recall curve for a binary classifier using scikit-learn. It tests correct use of the PR curve APIs and an understanding of why step-wise and interpolated PR areas give different numbers.

Compute average precision vs trapezoid AUC-PR with scikit-learn

Role: Data Scientist

Category: Machine Learning

Difficulty: medium

Interview Round: Other

Implement `ap_versus_trapezoid(y_true, y_proba)`. Given ground-truth binary labels and the predicted probabilities of the positive class (for example, from a logistic regression model), return the average precision and the trapezoidal area under the precision-recall curve as a 2-tuple of Python floats. The function must: - Return `(average_precision, trapezoid_auc)` in that order, both as Python `float`. - Compute `average_precision` with `sklearn.metrics.average_precision_score(y_true, y_proba)`. - Compute `trapezoid_auc` by calling `sklearn.metrics.precision_recall_curve(y_true, y_proba)` and then `sklearn.metrics.auc(recall, precision)`, with recall as the first argument. For example: ```text Input: y_true = [1, 0, 1, 0], y_proba = [0.9, 0.8, 0.7, 0.6] Output: (0.8333..., 0.7916...) ``` Here the average precision is 5/6 and the trapezoid area is 19/24, so the two summaries of the same curve disagree. ```hint Which argument is x `auc(x, y)` integrates y over x. Decide which of the two arrays is the horizontal axis of a PR curve before you call it. ``` ```hint Comparing the two areas Write both areas as sums over the recall increments and compare the precision value each one multiplies by an increment. ``` ### Constraints & Assumptions - `y_true` holds binary labels in {0, 1} and contains at least one positive. - `y_proba` is a 1-D array of the same length holding the probability of class 1 (the second column of `predict_proba`). - Inputs may be Python lists or NumPy arrays. ### What a Strong Answer Covers - Calls both scikit-learn routines as specified and returns Python floats in the required order. - Passes recall as the x argument of `auc` and a 1-D positive-class score to both metrics. - Explains how average precision weights each recall increment by the precision at that step, and how the trapezoid rule averages adjacent precision values instead. - Says when the trapezoid area falls below average precision, when it can exceed it, and what tied scores do. - Handles edge cases such as no positive labels or hard 0/1 predictions. ### Follow-up Questions - The trapezoid area under a PR curve is often called over-optimistic, yet on many inputs it comes out below average precision. When is it lower, when can it be higher, and why? - When would average precision and `auc(recall, precision)` nearly coincide? - What happens to each number if you pass hard 0/1 predictions from `predict` instead of probabilities? - Which of the two would you report when comparing models, and why?

Overview: Implement a function that returns both the average precision and the trapezoidal area under the precision-recall curve for a binary classifier using scikit-learn. It tests correct use of the PR curve APIs and an understanding of why step-wise and interpolated PR areas give different numbers.

PracHub logo
General
Nov 25, 2026
mediumData ScientistOtherMachine Learning
0
0

Implement ap_versus_trapezoid(y_true, y_proba). Given ground-truth binary labels and the predicted probabilities of the positive class (for example, from a logistic regression model), return the average precision and the trapezoidal area under the precision-recall curve as a 2-tuple of Python floats.

The function must:

  • Return (average_precision, trapezoid_auc) in that order, both as Python float .
  • Compute average_precision with sklearn.metrics.average_precision_score(y_true, y_proba) .
  • Compute trapezoid_auc by calling sklearn.metrics.precision_recall_curve(y_true, y_proba) and then sklearn.metrics.auc(recall, precision) , with recall as the first argument.

For example:

Input:  y_true = [1, 0, 1, 0], y_proba = [0.9, 0.8, 0.7, 0.6]
Output: (0.8333..., 0.7916...)

Here the average precision is 5/6 and the trapezoid area is 19/24, so the two summaries of the same curve disagree.

Constraints & Assumptions

  • y_true holds binary labels in {0, 1} and contains at least one positive.
  • y_proba is a 1-D array of the same length holding the probability of class 1 (the second column of predict_proba ).
  • Inputs may be Python lists or NumPy arrays.

What a Strong Answer Covers Guidance

  • Calls both scikit-learn routines as specified and returns Python floats in the required order.
  • Passes recall as the x argument of auc and a 1-D positive-class score to both metrics.
  • Explains how average precision weights each recall increment by the precision at that step, and how the trapezoid rule averages adjacent precision values instead.
  • Says when the trapezoid area falls below average precision, when it can exceed it, and what tied scores do.
  • Handles edge cases such as no positive labels or hard 0/1 predictions.

Follow-up Questions Guidance

  • The trapezoid area under a PR curve is often called over-optimistic, yet on many inputs it comes out below average precision. When is it lower, when can it be higher, and why?
  • When would average precision and auc(recall, precision) nearly coincide?
  • What happens to each number if you pass hard 0/1 predictions from predict instead of probabilities?
  • Which of the two would you report when comparing models, and why?