Implement Temperature Scaling and ECE for Logit Calibration

Quick Overview

Implement temperature scaling for a multiclass classifier in NumPy: a stable softmax, mean negative log-likelihood, a bounded fit of the temperature on validation logits, and top-label expected calibration error. Tests numerical stability, convex optimization and calibration metrics.

Implement Temperature Scaling and ECE for Logit Calibration

Role: Machine Learning Engineer

Category: Machine Learning

Difficulty: hard

Interview Round: Other

Given validation `logits` of shape `(n, k)` from a trained classifier and integer `labels` of shape `(n,)`, implement four NumPy functions: - `softmax_with_temperature(logits, temperature)` returns the numerically stable row-wise softmax of `logits / T`. - `negative_log_likelihood(logits, labels, temperature=1.0)` returns the mean natural-log negative log-likelihood (NLL) of the labels under that softmax. - `fit_temperature(logits, labels, t_min=0.05, t_max=20.0)` returns the $T$ in $[t_{\min}, t_{\max}]$ that minimizes the NLL. - `expected_calibration_error(probs, labels, n_bins=15)` returns the top-label expected calibration error (ECE) of a probability matrix. All scalars are returned as Python `float`. Example: ```python probs = [[0.85, 0.15], [0.75, 0.25], [0.35, 0.65], [0.45, 0.55]] labels = [0, 1, 1, 0] expected_calibration_error(probs, labels, n_bins=5) # 0.275 z = [[5.0, 0.0], [0.0, 5.0], [3.0, -1.0]] fit_temperature(z, [0, 1, 0]) # 0.05 (separable: clamps to t_min) fit_temperature(z, [1, 0, 1]) # 20.0 (all wrong: clamps to t_max) ``` ```hint A better parameter The NLL is awkward to study as a function of $T$. Rewrite it in terms of the inverse temperature and look at the sign of its second derivative. ``` ```hint Stable log-probabilities Large logits overflow `exp`, and tiny probabilities underflow to zero. Find a way to compute the NLL without ever taking the log of a softmax output. ``` ```hint The clamped cases Before any search, check which direction the objective is moving at each end of the allowed interval. ``` ### Constraints & Assumptions - Softmax and NLL must stay finite for logits with magnitude around `1e3`. - The fitted $T$ must be precise enough that the NLL gradient there is below `1e-8`. - If the optimum lies outside $[t_{\min}, t_{\max}]$, return the nearest bound. - ECE uses the row maximum as the confidence and `argmax` as the prediction. Bins are equal-width intervals `(lo, hi]`, and a confidence of 0 goes to bin 0. ECE is the sum over non-empty bins of $\frac{\text{count}}{n} \cdot |\text{accuracy} - \text{mean confidence}|$. An empty input returns `0.0`. - Raise `ValueError` when $T \le 0$, when the logits are not 2-D, when the labels do not have shape `(n,)` or fall outside $[0, k)$, or unless `0 < t_min < t_max`. ### What a Strong Answer Covers - A softmax and an NLL that stay finite for large logits. - An argument that the fitting problem has a single global optimum, and a search method that relies on it. - Correct handling of the cases where the optimum lies outside the interval. - ECE with the exact binning rule, including confidences of 0 and 1 and empty bins. - Every listed `ValueError` case, plus the time complexity of each function. ### Follow-up Questions - Why does temperature scaling never change accuracy, and when is a single temperature not enough? - Why is it convenient to optimize over the inverse temperature $\beta = 1/T$? - What are the weaknesses of binned ECE as a metric, and what would you report alongside it? - Why must the temperature be fit on held-out data, and what happens if you fit it on the training set?

Overview: Implement temperature scaling for a multiclass classifier in NumPy: a stable softmax, mean negative log-likelihood, a bounded fit of the temperature on validation logits, and top-label expected calibration error. Tests numerical stability, convex optimization and calibration metrics.

General logo
General
Nov 25, 2026
hardMachine Learning EngineerOtherMachine Learning
0
0

Given validation logits of shape (n, k) from a trained classifier and integer labels of shape (n,), implement four NumPy functions:

  • softmax_with_temperature(logits, temperature) returns the numerically stable row-wise softmax of logits / T .
  • negative_log_likelihood(logits, labels, temperature=1.0) returns the mean natural-log negative log-likelihood (NLL) of the labels under that softmax.
  • fit_temperature(logits, labels, t_min=0.05, t_max=20.0) returns the TT in [tmin⁡,tmax⁡][t_{\min}, t_{\max}] that minimizes the NLL.
  • expected_calibration_error(probs, labels, n_bins=15) returns the top-label expected calibration error (ECE) of a probability matrix.

All scalars are returned as Python float.

Example:

probs  = [[0.85, 0.15], [0.75, 0.25], [0.35, 0.65], [0.45, 0.55]]
labels = [0, 1, 1, 0]
expected_calibration_error(probs, labels, n_bins=5)  # 0.275

z = [[5.0, 0.0], [0.0, 5.0], [3.0, -1.0]]
fit_temperature(z, [0, 1, 0])  # 0.05 (separable: clamps to t_min)
fit_temperature(z, [1, 0, 1])  # 20.0 (all wrong: clamps to t_max)

Constraints & Assumptions

  • Softmax and NLL must stay finite for logits with magnitude around 1e3 .
  • The fitted TT must be precise enough that the NLL gradient there is below 1e-8 .
  • If the optimum lies outside [tmin⁡,tmax⁡][t_{\min}, t_{\max}] , return the nearest bound.
  • ECE uses the row maximum as the confidence and argmax as the prediction. Bins are equal-width intervals (lo, hi] , and a confidence of 0 goes to bin 0. ECE is the sum over non-empty bins of countn⋅∣accuracy−mean confidence∣\frac{\text{count}}{n} \cdot |\text{accuracy} - \text{mean confidence}| . An empty input returns 0.0 .
  • Raise ValueError when T≤0T \le 0 , when the logits are not 2-D, when the labels do not have shape (n,) or fall outside [0,k)[0, k) , or unless 0 < t_min < t_max .

What a Strong Answer Covers Guidance

  • A softmax and an NLL that stay finite for large logits.
  • An argument that the fitting problem has a single global optimum, and a search method that relies on it.
  • Correct handling of the cases where the optimum lies outside the interval.
  • ECE with the exact binning rule, including confidences of 0 and 1 and empty bins.
  • Every listed ValueError case, plus the time complexity of each function.

Follow-up Questions Guidance

  • Why does temperature scaling never change accuracy, and when is a single temperature not enough?
  • Why is it convenient to optimize over the inverse temperature β=1/T\beta = 1/T ?
  • What are the weaknesses of binned ECE as a metric, and what would you report alongside it?
  • Why must the temperature be fit on held-out data, and what happens if you fit it on the training set?