Design a predictive battery management system that flags failing cells

Quick Overview

Design a class that records voltage, temperature and current readings for battery cells, returns the latest reading and per-cell averages, and flags cells for maintenance with threshold and voltage-trend rules. It tests per-key state design, sliding-window checks, complexity under many calls, and careful edge-case handling.

Design a predictive battery management system that flags failing cells

Company: Tesla

Role: Software Engineer

Category: Software Engineering Fundamentals

Difficulty: medium

Interview Round: Other

Design a predictive battery management system (BMS) that monitors individual battery cells. Every reading for a cell holds a voltage, a temperature and a current. The system stores the history of readings for each cell, answers queries for the latest reading and for averages, and predicts which cells need maintenance. A cell is flagged for maintenance if any of these conditions holds: 1. The average voltage of the last 5 readings is below 3.0 V. 2. The average temperature of the last 5 readings is above 45.0 °C. 3. The average absolute current of the last 5 readings is above 10.0 A. 4. The voltage trend is declining: the average voltage of the last 3 readings is lower than the average voltage of the 3 readings before them. If a cell has fewer than 5 readings, conditions 1 to 3 use all of its readings. Condition 4 requires at least 6 readings. Implement a class `BatteryManagementSystem` with these methods: ```text addReading(cellId: int, voltage: float, temperature: float, current: float) -> None getLatestReading(cellId: int) -> List[float] getCellAverage(cellId: int) -> List[float] predictFailure(cellId: int) -> bool ``` - `addReading` adds a real-time reading for the given cell. - `getLatestReading` returns the most recent reading for the cell as `[voltage, temperature, current]`, or `[-1.0, -1.0, -1.0]` if the cell has no readings. - `getCellAverage` returns the average voltage, temperature and current across all readings for the cell as `[avgV, avgT, avgC]`, each rounded to 2 decimal places, or `[-1.0, -1.0, -1.0]` if the cell has no readings. - `predictFailure` analyzes the cell's history and returns `True` if the cell is flagged for maintenance, `False` otherwise. Example 1: ```text addReading(1, 3.7, 25.0, 2.0) addReading(1, 3.6, 26.0, -3.0) getLatestReading(1) -> [3.6, 26.0, -3.0] getCellAverage(1) -> [3.65, 25.5, -0.5] predictFailure(1) -> False getLatestReading(2) -> [-1.0, -1.0, -1.0] ``` Cell 1 has two readings, so every rule uses both. The average voltage is 3.65, the average temperature is 25.5 and the average absolute current is (2.0 + 3.0) / 2 = 2.5, all within limits, and two readings are too few for the trend rule. Cell 2 has never reported. Example 2: ```text addReading(3, 3.8, 40.0, 12.0) addReading(3, 3.8, 40.0, -12.0) getCellAverage(3) -> [3.8, 40.0, 0.0] predictFailure(3) -> True ``` The signed currents cancel, so the average current is 0.0. Condition 3 averages absolute values, which gives 12.0, above the 10.0 A limit. Example 3: ```text addReading(7, 4.0, 30.0, 1.0) addReading(7, 4.0, 30.0, 1.0) addReading(7, 4.0, 30.0, 1.0) addReading(7, 3.9, 30.0, 1.0) addReading(7, 3.9, 30.0, 1.0) predictFailure(7) -> False addReading(7, 3.9, 30.0, 1.0) predictFailure(7) -> True getCellAverage(7) -> [3.95, 30.0, 1.0] ``` After five readings every average is within limits (the average voltage is 3.96) and the trend rule cannot run yet. The sixth reading enables it: the last three voltages average 3.9 and the three before them average 4.0, so the trend is declining. The average over all six voltages is 23.7 / 6 = 3.95. ```hint Count the work Suppose most of the 10^5 calls hit one cell and alternate between addReading and getCellAverage. Estimate the total work of a straightforward implementation. ``` ```hint Read the rules literally Check each comparison for strictness, which quantity is averaged for current, and how many readings each rule needs before it applies. ``` ### Constraints & Assumptions - `1 <= cellId <= 10^4` - `0.0 <= voltage <= 5.0` - `-20.0 <= temperature <= 80.0` - `-50.0 <= current <= 50.0` - At most `10^5` calls are made in total across all methods. - If a cell has fewer than 5 readings, conditions 1 to 3 use all available readings. Condition 4 requires at least 6 readings. ### Clarifying Questions to Ask - Do readings for a cell always arrive in time order, or can a late reading carry an older timestamp? - Should `getLatestReading` round its values the way `getCellAverage` does, or return them as stored? - What should `predictFailure` return for a cell that has never reported? - Does the system need to keep every reading forever, or only enough history to answer these four methods? ### What a Strong Answer Covers - A per-cell structure that keeps readings in arrival order, with O(1) append and O(1) access to the newest reading. - The cost of `getCellAverage` when one cell receives most of the calls, and a way to answer it in O(1). - A `predictFailure` that reads only a fixed window of recent readings and gets the details right: fewer than 5 readings, the 6-reading minimum for the trend, strict comparisons, and the absolute value of current. - Correct results for unknown cells, with rounding applied only where the prompt asks for it. - How floating-point error behaves near the thresholds and at the rounding step. ### Follow-up Questions - Each cell reports once per second for years. How do you bound memory while keeping all four methods correct? - How would you make thresholds and window sizes configurable per battery chemistry, or add a fifth rule without editing `predictFailure`? - Sensor threads call `addReading` concurrently for different cells. What do you lock, and at what granularity? - How would you return every cell currently flagged for maintenance without scanning all cells?

Overview: Design a class that records voltage, temperature and current readings for battery cells, returns the latest reading and per-cell averages, and flags cells for maintenance with threshold and voltage-trend rules. It tests per-key state design, sliding-window checks, complexity under many calls, and careful edge-case handling.

Tesla logo
Tesla
Nov 24, 2026
mediumSoftware EngineerOtherSoftware Engineering Fundamentals
0
0

Design a predictive battery management system (BMS) that monitors individual battery cells. Every reading for a cell holds a voltage, a temperature and a current. The system stores the history of readings for each cell, answers queries for the latest reading and for averages, and predicts which cells need maintenance.

A cell is flagged for maintenance if any of these conditions holds:

  1. The average voltage of the last 5 readings is below 3.0 V.
  2. The average temperature of the last 5 readings is above 45.0 °C.
  3. The average absolute current of the last 5 readings is above 10.0 A.
  4. The voltage trend is declining: the average voltage of the last 3 readings is lower than the average voltage of the 3 readings before them.

If a cell has fewer than 5 readings, conditions 1 to 3 use all of its readings. Condition 4 requires at least 6 readings.

Implement a class BatteryManagementSystem with these methods:

addReading(cellId: int, voltage: float, temperature: float, current: float) -> None
getLatestReading(cellId: int) -> List[float]
getCellAverage(cellId: int) -> List[float]
predictFailure(cellId: int) -> bool
  • addReading adds a real-time reading for the given cell.
  • getLatestReading returns the most recent reading for the cell as [voltage, temperature, current] , or [-1.0, -1.0, -1.0] if the cell has no readings.
  • getCellAverage returns the average voltage, temperature and current across all readings for the cell as [avgV, avgT, avgC] , each rounded to 2 decimal places, or [-1.0, -1.0, -1.0] if the cell has no readings.
  • predictFailure analyzes the cell's history and returns True if the cell is flagged for maintenance, False otherwise.

Example 1:

addReading(1, 3.7, 25.0, 2.0)
addReading(1, 3.6, 26.0, -3.0)
getLatestReading(1)   -> [3.6, 26.0, -3.0]
getCellAverage(1)     -> [3.65, 25.5, -0.5]
predictFailure(1)     -> False
getLatestReading(2)   -> [-1.0, -1.0, -1.0]

Cell 1 has two readings, so every rule uses both. The average voltage is 3.65, the average temperature is 25.5 and the average absolute current is (2.0 + 3.0) / 2 = 2.5, all within limits, and two readings are too few for the trend rule. Cell 2 has never reported.

Example 2:

addReading(3, 3.8, 40.0, 12.0)
addReading(3, 3.8, 40.0, -12.0)
getCellAverage(3)     -> [3.8, 40.0, 0.0]
predictFailure(3)     -> True

The signed currents cancel, so the average current is 0.0. Condition 3 averages absolute values, which gives 12.0, above the 10.0 A limit.

Example 3:

addReading(7, 4.0, 30.0, 1.0)
addReading(7, 4.0, 30.0, 1.0)
addReading(7, 4.0, 30.0, 1.0)
addReading(7, 3.9, 30.0, 1.0)
addReading(7, 3.9, 30.0, 1.0)
predictFailure(7)     -> False
addReading(7, 3.9, 30.0, 1.0)
predictFailure(7)     -> True
getCellAverage(7)     -> [3.95, 30.0, 1.0]

After five readings every average is within limits (the average voltage is 3.96) and the trend rule cannot run yet. The sixth reading enables it: the last three voltages average 3.9 and the three before them average 4.0, so the trend is declining. The average over all six voltages is 23.7 / 6 = 3.95.

Constraints & Assumptions

  • 1 <= cellId <= 10^4
  • 0.0 <= voltage <= 5.0
  • -20.0 <= temperature <= 80.0
  • -50.0 <= current <= 50.0
  • At most 10^5 calls are made in total across all methods.
  • If a cell has fewer than 5 readings, conditions 1 to 3 use all available readings. Condition 4 requires at least 6 readings.

Clarifying Questions to Ask Guidance

  • Do readings for a cell always arrive in time order, or can a late reading carry an older timestamp?
  • Should getLatestReading round its values the way getCellAverage does, or return them as stored?
  • What should predictFailure return for a cell that has never reported?
  • Does the system need to keep every reading forever, or only enough history to answer these four methods?

What a Strong Answer Covers Guidance

  • A per-cell structure that keeps readings in arrival order, with O(1) append and O(1) access to the newest reading.
  • The cost of getCellAverage when one cell receives most of the calls, and a way to answer it in O(1).
  • A predictFailure that reads only a fixed window of recent readings and gets the details right: fewer than 5 readings, the 6-reading minimum for the trend, strict comparisons, and the absolute value of current.
  • Correct results for unknown cells, with rounding applied only where the prompt asks for it.
  • How floating-point error behaves near the thresholds and at the rounding step.

Follow-up Questions Guidance

  • Each cell reports once per second for years. How do you bound memory while keeping all four methods correct?
  • How would you make thresholds and window sizes configurable per battery chemistry, or add a fifth rule without editing predictFailure ?
  • Sensor threads call addReading concurrently for different cells. What do you lock, and at what granularity?
  • How would you return every cell currently flagged for maintenance without scanning all cells?